GB 5009.137 is the Chinese national food safety standard specifying the determination of antimony (Sb) in food products, with the current 2016 edition establishing hydride generation atomic fluorescence spectrometry (HG-AFS) as the core analytical technique. This article provides a comprehensive technical review of the standard, covering its scope and principle, applicable sample types, digestion and measurement procedures, quality control requirements, practical applications, and frequently asked questions for food safety professionals and laboratory practitioners.
Technical Overview
GB 5009.137-2016, the National Food Safety Standard for the Determination of Antimony in Food, is a mandatory analytical method standard published under China's food safety standard system. It superseded the previous GB/T 5009.137-2003 method and is applicable to virtually all categories of food, including grains, vegetables, fruits, meat, aquatic products, dairy products, beverages, edible oils, and packaged foods. The standard designates hydride generation atomic fluorescence spectrometry (HG-AFS) as its determination technique, reflecting the maturity and widespread availability of AFS instrumentation in Chinese food testing laboratories.
Antimony is a toxic metalloid with no known nutritional function in humans. Trivalent antimony compounds are generally more toxic than pentavalent forms, and the International Agency for Research on Cancer (IARC) has classified antimony trioxide as possibly carcinogenic to humans (Group 2B). Dietary exposure to antimony arises primarily from environmental contamination of raw agricultural commodities and from migration out of food-contact materials, most notably polyethylene terephthalate (PET) packaging, in which antimony trioxide is commonly used as a polycondensation catalyst, as well as glass, enamel, and ceramic ware. Because dietary intakes are typically very low, a highly sensitive and selective analytical method is required, which is precisely the role that GB 5009.137 fulfills.
The underlying measurement principle is as follows: the test portion is decomposed by acid digestion to destroy organic matter and bring antimony into solution; pentavalent antimony in the digest is pre-reduced to the trivalent state; in an acidic medium, borohydride reductant converts dissolved antimony to stibine (SbH3) gas; the hydride is swept by argon carrier gas into a heated quartz atomizer, where it is atomized in an argon-hydrogen flame; antimony atoms are then excited by characteristic radiation from an antimony hollow cathode lamp at 217.6 nm; and the resulting atomic fluorescence intensity, which is proportional to the antimony concentration, is compared against an external calibration curve for quantification.
Testing Samples
GB 5009.137 is broadly applicable across the food supply. Typical sample categories received by accredited third-party laboratories include the following:
Grains, Cereals, and Pulses
Rice, wheat flour, corn, oats, soybeans, and other cereals and pulses can accumulate antimony from soil and irrigation water. These samples are homogenized, and appropriate aliquots are digested for total antimony determination.
Vegetables, Fruits, and Edible Fungi
Leafy vegetables, root crops, fresh fruits, and cultivated or wild mushrooms are monitored because certain fungi and plants can take up antimony from contaminated soils. Edible algae and seaweed products, which can concentrate trace elements, are also frequently tested.
Meat, Poultry, Eggs, and Aquatic Products
Animal tissues, eggs, fish, crustaceans, and shellfish are analyzed as indicators of antimony transfer through the food chain. Liver, kidney, and other offal samples are of particular interest because antimony can partition into organs of excretion and metabolism.
Dairy Products, Beverages, and Drinking Water
Liquid matrices such as milk, yogurt, bottled water, juices, carbonated beverages, wine, and tea infusions are well suited to the method. PET-bottled beverages deserve special attention because prolonged storage, elevated temperatures, and acidic formulations can increase antimony migration from the packaging into the product.
Packaged Foods, Edible Oils, and Food-Contact Migration Solutions
Canned foods, condiments, sauces, and edible oils are tested for total antimony. In addition, migration test solutions prepared from food-contact materials in accordance with the GB 4806 series and GB 31604 series standards are commonly analyzed for antimony using the same hydride generation AFS technique, supporting compliance assessment of packaging components such as glass, enamel, ceramic, and plastic articles.
For sample submission, laboratories typically request at least 50–100 g of homogenized sample, or an equivalent representative portion for packaged products. Samples should be collected into clean polypropylene or polyethylene containers rather than glass vessels, since glass and enamel surfaces may contain antimony that can leach under acidic conditions. Samples should be transported chilled or frozen and analyzed promptly to preserve sample integrity.
Testing Items
The primary testing item under GB 5009.137 is the total antimony content of the food sample, reported as mass fraction in milligrams per kilogram (mg/kg) or micrograms per kilogram (μg/kg). Related analytical outputs typically include:
- Total antimony concentration in the digested sample solution (μg/L) and the corresponding mass fraction in the original sample (mg/kg or μg/kg).
- Method blank values and instrument detection limits, demonstrating analytical sensitivity at the low microgram-per-kilogram level.
- Calibration curve parameters, including linear range and correlation coefficient, supporting quantitative validity.
- Recovery rates of matrix-spiked samples and precision (relative deviation of replicates) as evidence of accuracy.
- Results for food-contact material migration solutions, expressed as antimony migration in mg/kg or mg/L of food simulant, when the method is applied in support of GB 4806 and GB 31604 compliance programs.
Testing Methods
Hydride Generation Atomic Fluorescence Spectrometry (HG-AFS)
Hydride generation AFS is the reference technique of GB 5009.137. The hydride generation step chemically separates antimony from the bulk sample matrix: stibine formed from antimony is physically separated from the liquid phase and transported to the atomizer, which substantially reduces spectral and matrix interferences and concentrates the analyte, yielding excellent sensitivity. The argon-hydrogen flame in the quartz atomizer provides a low-background environment for fluorescence measurement, and the antimony hollow cathode lamp emitting at the 217.6 nm resonance line ensures element-specific excitation. This combination enables reliable quantification of antimony far below the levels relevant to dietary risk assessment.
Sample Digestion Procedures
Sample decomposition is a critical step because antimony can be lost or poorly recovered if digestion is incomplete. The standard accommodates several digestion approaches:
- Microwave digestion: a weighed portion (typically 0.2–1.0 g of homogenized sample) is treated with nitric acid, often with a small addition of hydrogen peroxide, in sealed PTFE vessels under a programmed temperature ramp. This closed-vessel approach minimizes contamination and volatile losses and is the preferred method in modern laboratories.
- Wet digestion: the sample is heated with nitric acid, or nitric acid combined with perchloric or sulfuric acid, on a hot plate or block digestor until the solution becomes clear. Perchloric acid work must be performed in appropriate fume extraction facilities due to safety hazards.
- Pressure vessel digestion: samples are decomposed in sealed stainless-steel bombs with nitric acid in an oven, offering another closed-system option.
After digestion, the solution is diluted to a defined volume with water, and hydrochloric acid is added to establish the acidic medium required for hydride generation. A pre-reducing agent, commonly a thiourea–ascorbic acid solution, is then added to convert pentavalent antimony quantitatively to the trivalent state, and the solution is allowed to stand for a sufficient period (typically at least 30 minutes) before measurement to ensure complete prereduction.
Instrument Parameters and Calibration
Typical operating conditions for the AFS determination include the following, with exact settings optimized per instrument manufacturer guidance:
- Antimony hollow cathode lamp (or high-performance lamp) at the 217.6 nm analytical line, with lamp current and photomultiplier negative high voltage set within the manufacturer's recommended ranges.
- Dilute hydrochloric acid as the carrier solution feeding the hydride generation system.
- An alkaline potassium borohydride (or sodium borohydride) solution as the reducing reagent that generates stibine on-line.
- Argon as the carrier and shield gas, with flow rates adjusted for stable hydride transport and flame maintenance.
- A quartz tube atomizer operated at the specified temperature or with the argon-hydrogen flame ignition.
Calibration is performed with certified antimony standard solutions traceable to national metrology institutes. A series of working standards covering the expected concentration range (for example, 0 to 10 μg/L or up to 50 μg/L) is prepared in the same acid and pre-reductant matrix as the samples. A calibration curve is constructed from fluorescence intensity versus concentration, and a correlation coefficient of at least 0.995 (commonly ≥ 0.999) is expected. The antimony mass fraction in the sample is calculated from the measured concentration, the final volume, the sample mass, and any dilution factors, with reagent blank correction applied. Results are reported in mg/kg or μg/kg.
Quality Control and Data Integrity
Robust quality assurance is essential for trace-level antimony determination. Standard practice includes:
- Processing reagent blanks through the complete digestion and measurement procedure to monitor contamination from acids, vessels, and the laboratory environment.
- Analyzing samples in duplicate or triplicate to verify precision, with replicate agreement typically required within 20% relative deviation at trace levels.
- Performing matrix spike recovery tests, with acceptable recoveries generally in the range of 80%–120%.
- Verifying method accuracy using certified reference materials such as rice flour, tea leaf, or water CRMs where available.
- Running periodic calibration verification standards and instrument performance checks during the analytical sequence.
- Using high-purity reagents, acid-cleaned polypropylene or PTFE vessels, and a clean laboratory environment to minimize antimony blanks.
Complementary Techniques
Where multi-element data are required, GB 5009.268 (Determination of Multiple Elements in Foods by ICP-MS and ICP-OES) also covers antimony and allows simultaneous determination alongside elements such as lead, cadmium, arsenic, and mercury. International methods based on ICP-MS, including those aligned with ISO 17294-2 for water analysis, provide comparable capability. HG-AFS under GB 5009.137 remains highly cost-effective and sensitive for dedicated antimony determination, which is why it is the reference method for this element in the Chinese food safety standard system.
Applications
Testing to GB 5009.137 supports a wide range of food safety and regulatory activities:
- National surveillance and compliance monitoring: government food safety monitoring programs apply the method to screen food commodities for antimony contamination and to support risk assessment within China's national food safety framework.
- Packaging safety evaluation: manufacturers and importers use the method, together with the GB 4806 and GB 31604 series standards, to measure antimony migration from PET bottles, glassware, enamelware, ceramics, and plastic food-contact articles into food simulants.
- Drinking water and beverage quality control: bottlers and water suppliers verify antimony levels against the limit of 0.005 mg/L specified in the GB 5749 drinking water standard, particularly for acidic beverages stored in PET packaging.
- Import and export inspection: trade consignments are tested to demonstrate conformity with destination-market requirements for trace metal contaminants, facilitating customs clearance and contractual acceptance.
- Supply chain and raw material verification: food producers screen ingredients, water, and packaging components to control antimony inputs into finished products and to support supplier qualification programs.
- Research and total diet studies: academic institutions and public health agencies apply the method in dietary exposure assessments, environmental contamination studies, and investigations of antimony behavior during food processing and storage.
FAQ
What is the current version of GB 5009.137?
The current version is GB 5009.137-2016, the National Food Safety Standard for the Determination of Antimony in Food, which replaced GB/T 5009.137-2003. It establishes hydride generation atomic fluorescence spectrometry as the determination method and is applicable to all food categories.
Why is antimony monitored in food?
Antimony is a toxic metalloid with no nutritional benefit. The trivalent form is more toxic than the pentavalent form, and antimony trioxide is classified by IARC as possibly carcinogenic to humans (Group 2B). Main dietary concerns include environmental contamination of crops and migration from food-contact materials, especially PET packaging produced with antimony-based catalysts.
How sensitive is the method?
Hydride generation AFS routinely achieves detection at the low microgram-per-kilogram (ppb) level for food samples, depending on sample intake, final dilution volume, and instrument performance. This sensitivity is sufficient to verify compliance with the strictest antimony limits applicable to drinking water (0.005 mg/L under GB 5749) and food-contact migration requirements.
How much sample is needed and how should it be stored?
Laboratories generally require at least 50–100 g of homogenized sample. Samples should be stored in clean polypropylene or polyethylene containers rather than glass, kept chilled or frozen during transport, and analyzed as soon as practicable to minimize any change in antimony content or speciation.
What are the advantages of HG-AFS compared with ICP-MS?
HG-AFS offers excellent sensitivity for hydride-forming elements such as antimony at comparatively low equipment and operating cost, and the hydride generation step inherently separates the analyte from the matrix. ICP-MS, as specified in GB 5009.268, enables simultaneous multi-element determination and is advantageous when a full trace-metal profile is required. Many accredited third-party laboratories maintain both capabilities and select the technique based on project scope.
Does GB 2762 set maximum limits for antimony in food?
The contaminant standard GB 2762 does not currently assign maximum antimony levels to general food categories. Antimony control in China is focused on drinking water (GB 5749) and on migration limits for food-contact materials in the GB 4806 series, which makes sensitive analytical methods such as GB 5009.137 essential for surveillance and risk assessment.
What is a typical turnaround time for antimony testing?
For routine single-element determination, accredited laboratories commonly report results within five to ten working days after sample receipt, subject to sample load, complexity of the matrix, and whether repeat or confirmation analysis is required.
Why Choose ZKGX?
- State-of-the-art analytical equipment
- Highly qualified scientific team
- Fast turnaround time
- Competitive pricing