Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Determination of Thermal Insulation Performance of Thermal Insulation Materials

Thermal insulation performance determination measures the thermal conductivity, thermal resistance, and thermal transmittance of insulation materials using standardized steady-state and transient test methods. Accurate measurement is essential for building energy code compliance, product certification, and manufacturing quality control across construction, industrial, and cold-chain applications. This article outlines the key samples, testing items, measurement methods, and international standards involved in evaluating the heat insulation performance of thermal insulation materials.

Technical Overview

Thermal insulation performance describes the ability of a material to resist heat flow under a temperature gradient. It is quantified primarily through thermal conductivity (lambda, expressed in W/(m·K)), thermal resistance (R-value, expressed in m²·K/W), and thermal transmittance (U-value, expressed in W/(m²·K)). A lower thermal conductivity indicates better insulating capability, while a higher R-value indicates greater resistance to heat transfer through a given thickness.

Determination of these properties is typically performed under steady-state conditions, where a constant temperature difference is imposed across a specimen and the resulting heat flux is measured. Transient methods are also used for rapid screening, for high-temperature materials, and for determining additional properties such as thermal diffusivity and specific heat capacity. The choice of method depends on the material type, specimen geometry, operating temperature range, and required accuracy.

Testing is governed by internationally recognized standards published by ISO, ASTM, EN, and GB organizations. Results obtained by accredited third-party laboratories are widely used for product certification, declared value establishment, energy modeling, and regulatory compliance in the construction and industrial sectors.

Testing Samples

Foam Insulation Materials

Common specimens include expanded polystyrene (EPS), extruded polystyrene (XPS), rigid polyurethane (PUR), polyisocyanurate (PIR), and phenolic foam boards. These low-density cellular materials are supplied as flat panels, boards, or laminated composite boards, and their thermal conductivity is strongly influenced by cell gas composition, density, and aging behavior.

Fibrous Insulation Materials

Glass wool, rock (mineral) wool, and ceramic fiber products are tested in the form of mats, boards, felt, and pipe sections. Because fibrous materials are compressible, specimen thickness and density must be carefully controlled and reported, as both parameters significantly affect the measured thermal resistance.

Inorganic and High-Temperature Insulation Materials

This category includes calcium silicate boards, expanded perlite and vermiculite products, microporous silica insulation, and aerogel blankets. These materials are used at elevated service temperatures, so their thermal conductivity is frequently characterized as a function of temperature rather than at a single mean temperature point.

Reflective Insulation and Vacuum Insulation Panels

Multi-foil reflective insulation, radiant barriers, and vacuum insulation panels (VIPs) require specialized test configurations. Reflective systems depend on enclosed air gaps and are evaluated as assemblies, while VIPs demand careful edge protection and short test durations to avoid loss of vacuum during measurement.

Specimen Preparation and Conditioning

Specimens must be flat, parallel, and representative of the manufactured product, with dimensions meeting the apparatus requirements, typically 200 mm to 1000 mm square and 10 mm to 100 mm thick. Prior to testing, samples are conditioned to constant mass at a controlled temperature and humidity, and the density and thickness are measured and documented, as required by the applicable test standard.

Testing Items

The principal parameters determined in thermal insulation performance testing include:

  • Thermal conductivity (lambda value) at specified mean temperatures, commonly 10 °C, 23 °C, or application-relevant temperatures
  • Thermal resistance (R-value) for a given specimen thickness
  • Thermal transmittance (U-value) for building components and assemblies
  • Temperature dependence of thermal conductivity across the service temperature range
  • Thermal diffusivity and specific heat capacity by transient methods
  • Long-term thermal resistance (LTTR) and aged thermal conductivity for foams containing blowing agents
  • Declared thermal conductivity (lambda-D) and design thermal conductivity for product marking and energy calculations
  • Effect of moisture content on thermal performance

Testing Methods

Guarded Hot Plate Method

The guarded hot plate apparatus is the primary absolute reference method for determining steady-state thermal transmission properties. A centrally heated metering section surrounded by a guard ring creates one-dimensional heat flow through the specimen or specimen pair. The method, described in ISO 8302, ASTM C177, and GB/T 10294, achieves the highest accuracy and is used to certify reference materials and resolve measurement disputes. It is suitable for homogeneous insulation materials over a wide temperature range, typically up to 600 °C or higher with specialized equipment.

Heat Flow Meter Method

The heat flow meter method, specified in ISO 8301, ASTM C518, GB/T 10295, and EN 12667, measures heat flux through a specimen placed between two temperature-controlled plates using calibrated transducers. It is a comparative technique requiring calibration against certified reference materials traceable to national metrology institutes. Because of its speed, ease of operation, and good repeatability, it is the most widely used method for routine quality control and product certification of low-density insulation materials.

Guarded and Calibrated Hot Box Method

Hot box methods determine the thermal transmittance of larger building components such as walls, roofs, floors, doors, and complete assembly systems. A guarded hot box (ISO 8990, ASTM C1363, GB/T 13475) surrounds the metering chamber with a guard region to eliminate lateral heat losses, while a calibrated hot box applies correction factors determined in advance. These methods capture the effects of thermal bridging, joints, and fixings that plate methods cannot reproduce.

Pipe Insulation Test Methods

The thermal performance of preformed pipe insulation is determined using a guarded-end or calibrated hot pipe apparatus conforming to ISO 8497 and ASTM C335. A heated pipe of specified diameter is insulated with the test section, and heat loss per unit length is measured under steady-state conditions, yielding the linear thermal resistance of the installed system. This method is essential for industrial piping, district heating, and cryogenic applications.

Transient Methods

Transient techniques determine thermal properties from the time-dependent temperature response to a heat pulse. The transient plane source (hot disc) method per ISO 22007-2, the hot-wire method per ASTM C1113 for refractory materials, and the laser flash method per ASTM E1461 provide rapid measurement of thermal conductivity, diffusivity, and specific heat capacity. These methods are particularly valuable for small samples, high-temperature materials, and materials with moisture-sensitive or anisotropic structures.

Aging and Long-Term Performance Testing

Cellular plastic foams containing insulating blowing gases experience a gradual increase in thermal conductivity as air diffuses into the cells. Long-term thermal resistance is determined by the slicing and accelerated aging method of ASTM C1303, or through product-standard procedures such as those in EN 13164 and EN 13165, where specimens are stored at elevated temperature and periodically retested. The resulting aged value is used to establish declared lambda values for design purposes.

Applications

Determination of thermal insulation performance supports a broad range of engineering and regulatory activities, including:

  • Establishing declared thermal conductivity values for product certification and marking under EN and GB product standards
  • Compliance verification with national and international building energy codes and envelope requirements
  • Input data for building energy simulation, HVAC load calculation, and green building assessment
  • Quality control and process optimization in insulation manufacturing plants
  • Selection and verification of insulation for industrial equipment, boilers, furnaces, and piping systems
  • Thermal design of refrigerated vehicles, cold storage facilities, and cold-chain packaging
  • Verification of retrofit insulation performance in existing buildings
  • Research and development of advanced materials such as aerogels and vacuum insulation panels

FAQ

What is considered a good thermal conductivity value for insulation?

High-performance building insulation materials typically exhibit thermal conductivity between 0.020 and 0.040 W/(m·K) at a mean temperature of 10 °C or 23 °C. Polyurethane and phenolic foams generally fall near the lower end of this range, mineral wools in the middle, and fibrous loose-fill products toward the upper end. Vacuum insulation panels can achieve effective values below 0.008 W/(m·K).

What is the difference between the guarded hot plate and heat flow meter methods?

The guarded hot plate is an absolute method that derives thermal conductivity directly from measured electrical power, temperature difference, and specimen geometry, offering the highest accuracy. The heat flow meter is a secondary method that relies on calibration with certified reference materials but is faster and better suited to high-volume routine testing. Both methods, when properly implemented, produce results traceable to national standards.

At what temperature is thermal conductivity measured?

Most product standards specify a mean temperature of 10 °C for building applications, reflecting typical service conditions, while 23 °C or 25 °C is common for general characterization. For industrial and high-temperature insulation, measurements are performed at several mean temperatures to establish the conductivity-temperature curve required for design calculations.

How long does a steady-state thermal test take?

After the apparatus reaches thermal equilibrium, which may require several hours to more than a day depending on specimen thickness and density, the measurement itself is continued until multiple consecutive readings satisfy the stability criteria of the standard. A complete test, including conditioning and equilibrium, commonly requires one to two working days.

Why must foam plastics be tested for long-term aging?

Rigid foams initially contain blowing agent gases with thermal conductivity lower than air. Over time, air and moisture diffuse into the cells and the blowing agent diffuses out, increasing thermal conductivity. Aging tests determine the long-term thermal resistance so that designers can use realistic design values rather than the initially favorable, but non-durable, fresh value.

Can wet or moist insulation be tested accurately?

Moisture strongly increases apparent thermal conductivity and distorts steady-state results. Except for studies specifically investigating moisture effects, specimens are dried or conditioned to constant mass before testing, and the moisture content is reported with the results, as required by most test standards.